Products Catalog
- Surge Protective Device
- AC Contactor
- Circuit Breaker
- Miniature Circuit Breaker
- Moulded Case Circuit Breaker
- DZ518 Motor Starter
- Residual Circuit Breaker
- High Breaking Capacity Circuit Breaker
- Residual Current Circuit Breaker
- CDSM1 Breaker
- CDSM1N Series Breaker
- Intelligent Universal Circuit Breakers/Air Circuit Breaker
- Residual Current Breakers Overcurrent
- Residual Current Device
- Fuse
- Switch
- Micro Switch
- Tact Switch
- Bell
- Isolation Switch
- Pilot Lamp
- Staircase Switch
- Push Button Switch
- SB1 Control and Signalling ∅ 22 mm(fixing)
- SB2-E Plastic Control and Signalling ∅ 22mm(fixing)
- SB2-B Metal Control and Signalling ∅ 22mm(fixing)
- SAL-B Control stations and enclosures
- SB3 Control and Signalling ∅ 25、30mm(fixing)
- SB4 Metal Control and Signalling ∅ 22mm
- SB5 Plastic Control and Signalling ∅ 22mm
- SAL-D, K Control stations and enclosures
- SB6 Plastic Control and Signalling ∅ 16mm(fixing)
- SB8 Control and Signalling ∅ 22mm(fixing)
- SB9 Control and Signalling ∅ 22mm(fixing)
- SB10 Control and Signalling ∅ 22mm(fixing)
- AD58 signal indicator series φ16、22、25、30mm(fixing)
- BA9s series bulb with integral LED
- AD58 & SM buzzer units
- SM buzzer series
- Limit Switch
- Time switch
- Rotary Switch
- Rocker switch
- Terminal
- Connect Box
- MG03 Series
- Water-proof Connection Box
- 6 Ways Distribution Boxes A06 Series
- 6 Ways Distribution Boxes B06 Series
- 10 Ways Distribution Boxes A10 Series
- 11 Ways Distribution Boxes B11 Series
- 14 Ways Distribution Boxes B14 Series
- 12 Ways Distribution Boxes A12 Series
- 24 Ways Distribution Boxes A24 Series
- Control stations and enclosure
- Plug & Socket
- Sensor
- Transformer & Meter
- Relay
- Others
Model | AH3-N□ | ||
Dimension | 50H×40W×57.5D | ||
Mounting & Socket | Surface(-N) | PF083A(E) | |
Flush(-Y) | US-08 P3G-08 | ||
Full timing range | A:1S,10S,1M,10M; B:3S,30S,3M,30M; C:6S,60S,6M,60M; D:1M,10M,1H,10H; E:3M,30M,3H,30H | ||
Rated voltage | DC(V):12,24; AC(V): 12,24,110,220,240,380,50/60Hz | ||
Indicator operating | ON-UP Operating | ||
O/P contact | Model | Model A/B | |
Time limit 1C | 5A | ||
Time limit 2C | 5A | ||
Instantaneous 1C | 5A | ||
Life | Mechanical | 5×106 times | |
Electrical | 105 times | ||
Accuracy | Repeat error | ±1% max | |
Setting error | ±10% max | ||
Voltage error | ±1% max | ||
Temperature error | ±2% max | ||
Reset time | 0.1 sec max | ||
Consumed power | 2VA | ||
Ambient temperature | -10℃~+55℃ | ||
Ambient humidity | 48~85%RH | ||
Weight | 160g |