Products Catalog
- Surge Protective Device
- AC Contactor
- Circuit Breaker
- Miniature Circuit Breaker
- Moulded Case Circuit Breaker
- DZ518 Motor Starter
- Residual Circuit Breaker
- High Breaking Capacity Circuit Breaker
- Residual Current Circuit Breaker
- CDSM1 Breaker
- CDSM1N Series Breaker
- Intelligent Universal Circuit Breakers/Air Circuit Breaker
- Residual Current Breakers Overcurrent
- Residual Current Device
- Fuse
- Switch
- Micro Switch
- Tact Switch
- Bell
- Isolation Switch
- Pilot Lamp
- Staircase Switch
- Push Button Switch
- SB1 Control and Signalling ∅ 22 mm(fixing)
- SB2-E Plastic Control and Signalling ∅ 22mm(fixing)
- SB2-B Metal Control and Signalling ∅ 22mm(fixing)
- SAL-B Control stations and enclosures
- SB3 Control and Signalling ∅ 25、30mm(fixing)
- SB4 Metal Control and Signalling ∅ 22mm
- SB5 Plastic Control and Signalling ∅ 22mm
- SAL-D, K Control stations and enclosures
- SB6 Plastic Control and Signalling ∅ 16mm(fixing)
- SB8 Control and Signalling ∅ 22mm(fixing)
- SB9 Control and Signalling ∅ 22mm(fixing)
- SB10 Control and Signalling ∅ 22mm(fixing)
- AD58 signal indicator series φ16、22、25、30mm(fixing)
- BA9s series bulb with integral LED
- AD58 & SM buzzer units
- SM buzzer series
- Limit Switch
- Time switch
- Rotary Switch
- Rocker switch
- Terminal
- Connect Box
- MG03 Series
- Water-proof Connection Box
- 6 Ways Distribution Boxes A06 Series
- 6 Ways Distribution Boxes B06 Series
- 10 Ways Distribution Boxes A10 Series
- 11 Ways Distribution Boxes B11 Series
- 14 Ways Distribution Boxes B14 Series
- 12 Ways Distribution Boxes A12 Series
- 24 Ways Distribution Boxes A24 Series
- Control stations and enclosure
- Plug & Socket
- Sensor
- Transformer & Meter
- Relay
- Others
Model | ATDV-Y | |
Dimension | 88H×58W×68D | |
Mounting & Socket | Surface(-N) | |
Flush(-Y) | US-08 P3G-08 | |
Full timing range | 6S×6S, 6S×60S, 60S×6S, 60S×60S, 6M×6M, 6M×60M, 60M ×6M, 60M×60M, Longest time 12 hours upon clients' request | |
Rated voltage | AC(V):12,24,110,220,240,50/60Hz; DC(V):12,24 | |
Indicator operating | ON,OFF operating | |
O/P contact | Model | ATDV-Y |
Time limit 1C | 5A | |
Time limit 2C | ||
Instantaneous 1C | ||
Life | Mechanical | 5×106 times |
Electrical | 105 times | |
Accuracy | Repeat error | ±2% max |
Setting error | ±20% max | |
Voltage error | ±1% max | |
Temperature error | ±2% max | |
Reset time | 0.2 sec max | |
Consumed power | 2VA | |
Ambient temperature | -10℃~+55℃ | |
Ambient humidity | 48~85%RH | |
Weight | 210g |