Products Catalog
- Surge Protective Device
- AC Contactor
- Circuit Breaker
- Miniature Circuit Breaker
- Moulded Case Circuit Breaker
- DZ518 Motor Starter
- Residual Circuit Breaker
- High Breaking Capacity Circuit Breaker
- Residual Current Circuit Breaker
- CDSM1 Breaker
- CDSM1N Series Breaker
- Intelligent Universal Circuit Breakers/Air Circuit Breaker
- Residual Current Breakers Overcurrent
- Residual Current Device
- Fuse
- Switch
- Micro Switch
- Tact Switch
- Bell
- Isolation Switch
- Pilot Lamp
- Staircase Switch
- Push Button Switch
- SB1 Control and Signalling ∅ 22 mm(fixing)
- SB2-E Plastic Control and Signalling ∅ 22mm(fixing)
- SB2-B Metal Control and Signalling ∅ 22mm(fixing)
- SAL-B Control stations and enclosures
- SB3 Control and Signalling ∅ 25、30mm(fixing)
- SB4 Metal Control and Signalling ∅ 22mm
- SB5 Plastic Control and Signalling ∅ 22mm
- SAL-D, K Control stations and enclosures
- SB6 Plastic Control and Signalling ∅ 16mm(fixing)
- SB8 Control and Signalling ∅ 22mm(fixing)
- SB9 Control and Signalling ∅ 22mm(fixing)
- SB10 Control and Signalling ∅ 22mm(fixing)
- AD58 signal indicator series φ16、22、25、30mm(fixing)
- BA9s series bulb with integral LED
- AD58 & SM buzzer units
- SM buzzer series
- Limit Switch
- Time switch
- Rotary Switch
- Rocker switch
- Terminal
- Connect Box
- MG03 Series
- Water-proof Connection Box
- 6 Ways Distribution Boxes A06 Series
- 6 Ways Distribution Boxes B06 Series
- 10 Ways Distribution Boxes A10 Series
- 11 Ways Distribution Boxes B11 Series
- 14 Ways Distribution Boxes B14 Series
- 12 Ways Distribution Boxes A12 Series
- 24 Ways Distribution Boxes A24 Series
- Control stations and enclosure
- Plug & Socket
- Sensor
- Transformer & Meter
- Relay
- Others
DZ108(3VE) series moulded case circuit breaker(MCCB) is suitable to be used in circuit of rated voltage up up to AC 660V 50/60Hz,rated current form 0.1 to 63A. They are applicable for toprevent small capacity motor,circuit from overload and short circuit. They also canbe used as direct starter for starting the motor and a switch for change over the circuit under normal conditions.
Type |
Rated current (A) |
The The heat release delay current setting range (A) |
The instantaneous electromagnetic tripping current setting | Auxiliary contact selection |
DZ108-20 (3VE1) |
0.16 | 0.1-0.16 | 1.9 |
Without anxiliary contact |
0.25 | 0.16-0.25 | 3 | ||
0.4 | 0.25-0.4 | 4.8 | ||
0.63 | 0.4-0.63 | 7.5 | ||
1 | 0.63-1 | 12 | 1NO+1NC | |
1.6 | 1-1.6 | 19.2 | ||
2.5 | 1.6-2.5 | 30 | ||
3.2 | 2-3.2 | 38 | ||
4 | 2.5-4 | 48 | 2NO | |
5 | 3.2-5 | 60 | ||
6.3 | 4-6.3 | 75 | ||
8 | 5-8 | 96 | ||
10 | 6.3-10 | 120 | 2NC | |
12 | 8-12.5 | 150 | ||
16 | 10-16 | 192 | ||
20 | 14-20 | 210 |