Products Catalog
- Surge Protective Device
- AC Contactor
- Circuit Breaker
- Miniature Circuit Breaker
- Moulded Case Circuit Breaker
- DZ518 Motor Starter
- Residual Circuit Breaker
- High Breaking Capacity Circuit Breaker
- Residual Current Circuit Breaker
- CDSM1 Breaker
- CDSM1N Series Breaker
- Intelligent Universal Circuit Breakers/Air Circuit Breaker
- Residual Current Breakers Overcurrent
- Residual Current Device
- Fuse
- Switch
- Micro Switch
- Tact Switch
- Bell
- Isolation Switch
- Pilot Lamp
- Staircase Switch
- Push Button Switch
- SB1 Control and Signalling ∅ 22 mm(fixing)
- SB2-E Plastic Control and Signalling ∅ 22mm(fixing)
- SB2-B Metal Control and Signalling ∅ 22mm(fixing)
- SAL-B Control stations and enclosures
- SB3 Control and Signalling ∅ 25、30mm(fixing)
- SB4 Metal Control and Signalling ∅ 22mm
- SB5 Plastic Control and Signalling ∅ 22mm
- SAL-D, K Control stations and enclosures
- SB6 Plastic Control and Signalling ∅ 16mm(fixing)
- SB8 Control and Signalling ∅ 22mm(fixing)
- SB9 Control and Signalling ∅ 22mm(fixing)
- SB10 Control and Signalling ∅ 22mm(fixing)
- AD58 signal indicator series φ16、22、25、30mm(fixing)
- BA9s series bulb with integral LED
- AD58 & SM buzzer units
- SM buzzer series
- Limit Switch
- Time switch
- Rotary Switch
- Rocker switch
- Terminal
- Connect Box
- MG03 Series
- Water-proof Connection Box
- 6 Ways Distribution Boxes A06 Series
- 6 Ways Distribution Boxes B06 Series
- 10 Ways Distribution Boxes A10 Series
- 11 Ways Distribution Boxes B11 Series
- 14 Ways Distribution Boxes B14 Series
- 12 Ways Distribution Boxes A12 Series
- 24 Ways Distribution Boxes A24 Series
- Control stations and enclosure
- Plug & Socket
- Sensor
- Transformer & Meter
- Relay
- Others
·DESCRIPTION
The DP series current transformer has been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar circuit. The connection of conventional CTs usually requires the interruption of the primary side circuit to pass cables or bur-bars through the transformer core or to connect such cables to the primary terminals. The DBP series transformers core may be easily opened and they may be installed and connected without any supply interruption. Thus saving time and the installation costs.
·FEATURE
Two built in fixing methods:Base; Busbar mounting
Very easy to mounting.
Wide inner window, allowing clamping of big cables or bus-bars.Wide range of sizes to accommodate all the existing installations.
Primary current from 5A to 5000A.
·SPECIFICAIONS
Rated Frequency 50/60Hz
Rated test voltage 3kV AC. (1 min)
Rated short-time thermal current(Ith) 60In
Rated dynamic current,(Idyn) 2.5Ith
Rated voltage,(Um) 0.72Kv AC.
Continuous overload,(Id) 1.2In
Operating temperature -10℃~50℃
Housing self-extinguishing class VO
Safety factor FS 5
Secondary current 5A/1A