Products Catalog
- Surge Protective Device
- AC Contactor
- Circuit Breaker
- Miniature Circuit Breaker
- Moulded Case Circuit Breaker
- DZ518 Motor Starter
- Residual Circuit Breaker
- High Breaking Capacity Circuit Breaker
- Residual Current Circuit Breaker
- CDSM1 Breaker
- CDSM1N Series Breaker
- Intelligent Universal Circuit Breakers/Air Circuit Breaker
- Residual Current Breakers Overcurrent
- Residual Current Device
- Fuse
- Switch
- Micro Switch
- Tact Switch
- Bell
- Isolation Switch
- Pilot Lamp
- Staircase Switch
- Push Button Switch
- SB1 Control and Signalling ∅ 22 mm(fixing)
- SB2-E Plastic Control and Signalling ∅ 22mm(fixing)
- SB2-B Metal Control and Signalling ∅ 22mm(fixing)
- SAL-B Control stations and enclosures
- SB3 Control and Signalling ∅ 25、30mm(fixing)
- SB4 Metal Control and Signalling ∅ 22mm
- SB5 Plastic Control and Signalling ∅ 22mm
- SAL-D, K Control stations and enclosures
- SB6 Plastic Control and Signalling ∅ 16mm(fixing)
- SB8 Control and Signalling ∅ 22mm(fixing)
- SB9 Control and Signalling ∅ 22mm(fixing)
- SB10 Control and Signalling ∅ 22mm(fixing)
- AD58 signal indicator series φ16、22、25、30mm(fixing)
- BA9s series bulb with integral LED
- AD58 & SM buzzer units
- SM buzzer series
- Limit Switch
- Time switch
- Rotary Switch
- Rocker switch
- Terminal
- Connect Box
- MG03 Series
- Water-proof Connection Box
- 6 Ways Distribution Boxes A06 Series
- 6 Ways Distribution Boxes B06 Series
- 10 Ways Distribution Boxes A10 Series
- 11 Ways Distribution Boxes B11 Series
- 14 Ways Distribution Boxes B14 Series
- 12 Ways Distribution Boxes A12 Series
- 24 Ways Distribution Boxes A24 Series
- Control stations and enclosure
- Plug & Socket
- Sensor
- Transformer & Meter
- Relay
- Others
Type | Main circuit contactor | Standard thermal relay | Control motor power | With fuse | ||||||
KM2 used for separate | KM1 used for Y operation | KM3 used for normal operation | Current stability range (A) | The type of thermal relay | 220V | 380V | 415V | 440V | ||
QJX2-123 | KJC1(CJX2)-1210 | KJC1(CJX2)-0901 | KJC1(CJX2)-1201 | 10~13 | JRS4-12316 | 5.5 | 10 | 10 | 10 | 20 |
QJX2-183 | KJC1(CJX2)-1810 | KJC1(CJX2)-1201 | KJC1(CJX2)-1801 | 13~18 | JRS4-16321 | 17.5 | 15 | 15 | 15 | 32 |
QJX2-253 | KJC1(CJX2)-2510 | KJC1(CJX2)-1201 | KJC1(CJX2)-2501 | 18~25 | JRS4-25322 | 11 | 18.5 | 22 | 22 | 50 |
QJX2-323 | KJC1(CJX2)-3210 | KJC1(CJX2)-2501 | KJC1(CJX2)-3201 | 23~32 | JRS4-32353 | 15 | 25 | 25 | 30 | 63 |
QJX2-403 | KJC1(CJX2)-4011 | KJC1(CJX2)-2501 | KJC1(CJX2)-4011 | 30~40 | JRS4-40355 | 18.5 | 33 | 37 | 37 | 80 |
QJX2-503 | KJC1(CJX2)-5011 | KJC1(CJX2)-4011 | KJC1(CJX2)-5011 | 48~57 | JRS4-63359 | 25 | 46 | 45 | 45 | 100 |
QJX2-653 | KJC1(CJX2)-6511 | KJC1(CJX2)-4011 | KJC1(CJX2)-6511 | 57~66 | JRS4-63361 | 30 | 55 | 59 | 59 | 125 |
QJX2-803 | KJC1(CJX2)-8011 | KJC1(CJX2)-5011 | KJC1(CJX2)-8011 | 63~80 | JRS4-80363 | 40 | 75 | 75 | 75 | 160 |
QJX2-953 | KJC1(CJX2)-9511 | KJC1(CJX2)-6511 | KJC1(CJX2)- | 75~105 | JRS4-14065 | 40 | 80 | 80 | 80 | 200 |
QJX2-123 | QJX2-183 | QJX2-253 | QJX2-323 | QJX2-403 | QJX2-503 | QJX2-653 | QJX2-803 | QJX2-953 | ||
Rated working current Ie (AC-3 under 380V) A | 20 | 31 | 43 | 56 | 69 | 86 | 109 | 138 | 164 | |
Rated insulation voltage Ui V | 660(690) | |||||||||
Rated working voltage Ue V | 380 | |||||||||
Standard | GB140484 | |||||||||
AC-3 380V electrical life (times) | 55 thousand times | 25 thousand times | 20 thousand times | 15 thousand times | ||||||
Mechanical life (times) | 300 | |||||||||
Rated working voltage of auxiliary circuit V | AC 380V, DC 220V | |||||||||
Rated working current of auxiliary circuit A | 10 | |||||||||
Coil | Pull-in voltage | 0.85~1.1 | ||||||||
release voltage | 0.2~0.75 |